Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.397
Filtrar
1.
Int Ophthalmol ; 44(1): 186, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643220

RESUMO

PURPOSE: This study introduces the Order of Magnitude (OM), a cost-effective, indigenous, virtual reality-based visual field analyzer designed for detecting glaucomatous visual field loss. METHODS: The OM test employs a two-step supra-thresholding algorithm utilizing stimuli of 0.43°diameter (equivalent to Goldmann size III) at low and high thresholds. A comparative analysis was conducted against the Humphrey visual field (HVF) test, considered the gold standard in clinical practice. Participants, including those with glaucoma and normal individuals, underwent comprehensive eye examinations alongside the OM and HVF tests between April and October 2019. Diagnostic sensitivity and specificity of the OM test were assessed against clinical diagnoses made by specialists. RESULTS: We studied 157 eyes (74 glaucomatous, 83 control) of 152 participants. Results demonstrated a high level of reliability for both OM and HVF tests, with no significant difference observed (P = 0.19, Chi-square test). The sensitivity and specificity of the OM test were found to be 93% (95% CI 86-100%) and 83% (95% CI 72.4-93%), respectively, while the HVF test showed sensitivity and specificity of 98% (95% CI 93.9-100%) and 83% (95% CI 73.9-92.8%), respectively. CONCLUSION: These findings suggest that the OM test is non-inferior to the reference standard HVF test in identifying glaucomatous visual field loss.


Assuntos
Glaucoma , Campos Visuais , Humanos , Reprodutibilidade dos Testes , Glaucoma/diagnóstico , Testes de Campo Visual/métodos , Transtornos da Visão/diagnóstico , Sensibilidade e Especificidade
2.
BMC Ophthalmol ; 24(1): 159, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600474

RESUMO

BACKGROUND: Multifocal pupillographic objective perimetry (mfPOP) is a novel method for assessing functional change in diseases like glaucoma. Previous research has suggested that, in contrast to the pretectally-mediated melanopsin response of intrinsically photosensitive retinal ganglion cells, mfPOP responses to transient onset stimuli involve the extrastriate cortex, and thus the main visual pathway. We therefore investigate the correlation between peripapillary retinal nerve fibre layer (pRNFL) thickness and glaucomatous visual field changes detected using mfPOP. Parallel analyses are undertaken using white on white standard automated perimetry (SAP) for comparison. METHODS: Twenty-five glaucoma patients and 24 normal subjects were tested using SAP, 3 mfPOP variants, and optical coherence tomography (OCT). Arcuate clusters of the SAP and mfPOP deviations were weighted according to their contribution to published arcuate divisions of the retinal nerve fibre layer. Structure-function correlation coefficients (r) were computed between pRNFL clock-hour sector thickness measurements, and the local visual field sensitivities from both SAP and mfPOP. RESULTS: The strongest correlation was observed in the superior-superotemporal disc sector in patients with worst eye SAP MD < -12 dB: r = 0.93 for the mfPOP LumBal test (p < 0.001). Correlations across all disc-sectors were strongest in these same patients in both SAP and mfPOP: SAP r = 0.54, mfPOP LumBal r = 0.55 (p < 0.001). In patients with SAP MD ≥ -6 dB in both eyes, SAP correlations across all sectors were higher than mfPOP; mfPOP correlations however, were higher than SAP in more advanced disease, and in normal subjects. CONCLUSIONS: For both methods the largest correlations with pRNFL thickness corresponded to the inferior nasal field of more severely damaged eyes. Head-to-head comparison of mfPOP and SAP showed similar structure-function relationships. This agrees with our recent reports that mfPOP primarily stimulates the cortical drive to the pupils.


Assuntos
Glaucoma , Testes de Campo Visual , Humanos , Testes de Campo Visual/métodos , Retina , Tomografia de Coerência Óptica/métodos , Fibras Nervosas , Relação Estrutura-Atividade
3.
Int Ophthalmol ; 44(1): 196, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662242

RESUMO

PURPOSE: Some patients refrained from seeking an ophthalmologist due to the anxiety and morbidity associated with the coronavirus disease (COVID-19) pandemic. We investigated progressive visual field defects in patients with glaucoma who refrained from ophthalmological examinations. METHODS: This was a retrospective study. We analyzed data from 886 patients with glaucoma who visited Inouye Eye Hospital in June 2022 and were followed-up prior to January 2020. We examined the number of times patients canceled visits between January 2020 and May 2022 due to coronavirus concerns. We assessed the mean deviation (MD) values of the Humphrey Visual Field Assessment (HFA) program 30-2 SITA Standard values after visit interruptions for worsening beyond the MD values predicted by the MD slope. Factors influencing this difference were analyzed using logistic regression analysis. RESULTS: The study included 374 men and 512 women. The mean age was 68.7 ± 12.0 years. Visit interruptions occurred in 146 patients (16.5%), with 95 (65.1%) rescheduling once, 27 (18.5%) twice, and 24 (16.4%) three or more times. Among 90 patients who underwent HFA regularly, 50 (55.6%) experienced worse-than-expected MD values and 12 (13.3%) deteriorated by 2 dB or more. Longer interruptions and high intraocular pressure before interruption worsened the MD values by 2 dB or more. CONCLUSION: Patients with glaucoma with visit interruptions due to the pandemic should be monitored for the progression of visual field impairment.


Assuntos
COVID-19 , Progressão da Doença , Glaucoma , SARS-CoV-2 , Campos Visuais , Humanos , COVID-19/epidemiologia , Masculino , Feminino , Estudos Retrospectivos , Idoso , Glaucoma/epidemiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Pandemias , Testes de Campo Visual , Pressão Intraocular/fisiologia , Idoso de 80 Anos ou mais
4.
PLoS One ; 19(4): e0301419, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38573981

RESUMO

Perimetry, or visual field test, estimates differential light sensitivity thresholds across many locations in the visual field (e.g., 54 locations in the 24-2 grid). Recent developments have shown that an entire visual field may be relatively accurately reconstructed from measurements of a subset of these locations using a linear regression model. Here, we show that incorporating a dimensionality reduction layer can improve the robustness of this reconstruction. Specifically, we propose to use principal component analysis to transform the training dataset to a lower dimensional representation and then use this representation to reconstruct the visual field. We named our new reconstruction method the transformed-target principal component regression (TTPCR). When trained on a large dataset, our new method yielded results comparable with the original linear regression method, demonstrating that there is no underfitting associated with parameter reduction. However, when trained on a small dataset, our new method used on average 22% fewer trials to reach the same error. Our results suggest that dimensionality reduction techniques can improve the robustness of visual field testing reconstruction algorithms.


Assuntos
Testes de Campo Visual , Campos Visuais , Testes de Campo Visual/métodos , Limiar Sensorial , Algoritmos , Análise de Regressão
5.
Jpn J Ophthalmol ; 68(2): 117-125, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38498066

RESUMO

PURPOSE: To report aging-associated change rates in circumpapillary retinal nerve fiber layer thickness (cpRNFLT) and macular ganglion cell-inner plexiform layer and complex thickness (MGCIPLT, MGCCT) in normal Japanese eyes and to compare the data in linear scaled visual field (VF) sensitivity of central 4 points of Humphrey Field Analyzer (HFA) 24-2 test (VF4TestPoints) to that in MGCIPLT in four 0.6-mm-diameter circles corresponding to the four central points of HFA 24-2 adjusted for retinal ganglion cell displacement (GCIPLT4TestPoints). STUDY DESIGN: Prospective observational study METHODS: HFA 24-2 tests and spectral-domain optical coherence tomography (SD-OCT) measurements of cpRNFLT, MGCIPLT, MGCCT and GCIPLT4TestPoints were performed every 3 months for 3 years in 73 eyes of 37 healthy Japanese with mean age of 50.4 years. The time changes of SD-OCT-measured parameters and VF4TestPoints were analyzed using a linear mixed model. RESULTS: The aging-associated change rates were -0.064 µm/year for MGCIPLT and and -0.095 for MGCCT (P=0.020 and 0.017), but could not be detected for cpRNFLT. They accelerated with aging at -0.009µm/year/year of age for MGCIPLT (P<0.001), at 0.011 for MGCCT (P<0.001) and at 0.013 for cpRNFLT(0.031). The aging-associated decline of -82.1 [1/Lambert]/year of VF4TestPoints corresponded to -0.095 µm/year of GCIPLT4TestPoints. CONCLUSION: We report that aging-associated change rates of cpRNFLT, MGCIPLT and MGCCT in normal Japanese eyes were found to be significantly accelerated along with aging. Relationship between VF sensitivity decline rates and SD-OCT measured GCIPLT decline rates during physiological aging in the corresponding parafoveal retinal areas are also documented.


Assuntos
Retina , Tomografia de Coerência Óptica , Humanos , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos , Japão/epidemiologia , Células Ganglionares da Retina , Envelhecimento , Testes de Campo Visual
6.
Transl Vis Sci Technol ; 13(3): 10, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488433

RESUMO

Purpose: Compare estimated sensitivities of SITA-Standard to the RATA-Standard algorithm of the Radius virtual reality perimeter (VRP), and measure concordance in glaucoma staging. Methods: One hundred adult glaucoma patients-half with suspect or mild glaucoma, and half with moderate or severe-from five clinics performed four 24-2 visual field tests during a single visit, two with the Humphrey Field Analyzer (HFA) and two with Radius, in randomized order: HRHR or RHRH. Only one eye was tested per participant. We used the Wilcoxon rank sum test with Bonferroni correction to compare distributions of estimated sensitivities across all 54 test locations over the 15 to 40 dB measurement range of the Radius. Weighted kappa measured concordance in glaucoma staging between two masked glaucoma experts using Medicare definitions of severity. Results: A total of 62 OD and 38 OS eyes were tested. Estimated sensitivities for SITA-Standard and RATA-Standard were not significantly different for OD, but were for OS-likely because of SITA-Standard OD and OS being significantly different in our sample, but not for RATA-Standard. Low agreement was observed between 15 to 22 dB. Concordance in glaucoma staging was high for both graders: kappa = 0.91 and kappa = 0.93. Average test duration was 298 seconds for RATA-Standard and 341 seconds for SITA-Standard. The correlation in mean deviation was 0.94. Conclusions: Estimated sensitivities of RATA-Standard are comparable to SITA-Standard between 23 to 40 dB with high concordance in glaucoma staging. Translational Relevance: Radius VRP is statistically noninferior to HFA when staging glaucoma using Medicare definitions.


Assuntos
Glaucoma , Realidade Virtual , Dispositivos Eletrônicos Vestíveis , Idoso , Estados Unidos , Adulto , Humanos , Campos Visuais , Transtornos da Visão , Reprodutibilidade dos Testes , Medicare , Glaucoma/diagnóstico , Testes de Campo Visual/métodos
7.
Arq Bras Oftalmol ; 87(3): e20220366, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537042

RESUMO

PURPOSE: To evaluate the saccadic movements of patients with visual field loss due to primary open-angle glaucoma. METHODS: Thirteen patients with good visual acuity (0.2 logMAR or better) (seven patients with primary open-angle glaucoma 65 ± 13 years) and six controls (51 ± 6 years) yielded a comprehensive ophthalmological examination, including Humphrey Visual Field tests (SITA-Standard 24-2), and performed a monocular, exploratory digital visual search task that quantifies the duration for finding the number "4" on a random array of digits distributed on the screen. After individual adjustments of the angle and distance positioning, the screen was spatially matched with the 24-2 visual field, and divided into five areas for analysis. During the task, saccades were simultaneously recorded in the same eye with a video-based eye tracker. RESULTS: The patients with primary open-angle glaucoma showed a significantly higher number of saccades/screen (median ± interquartile range, 59.00 ± 29.00 vs. 32.50 ± 19.75 saccades (p=0.027) and visual search time per screen (38.50 ± 60.14 vs. 23.75 ± 8.90 seconds (p=0.035) than the controls did. Although the univariate analysis indicated a significant correlation with visual field mean deviation (coefficient=26.19 (p=0.02), only the visual search time/screen was significantly associated with the number of saccades/screen in the multivariate regression model (coefficient=0.55 (p<0.001). Overall, no significant correlation was observed between the sectorial number of saccades and the sensitivity of the five visual field areas. CONCLUSIONS: The patients with primary open-angle glaucoma show impaired search performance and showed a higher number of saccades needed to find stimuli when performing the exploratory visual task.


Assuntos
Glaucoma de Ângulo Aberto , Testes de Campo Visual , Humanos , Campos Visuais , Transtornos da Visão/diagnóstico , Movimentos Sacádicos
8.
PLoS One ; 19(3): e0299129, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38427630

RESUMO

OBJECTIVE: It is currently still unknown why some drivers with visual field loss can compensate well for their visual impairment while others adopt ineffective strategies. This paper contributes to the methodological investigation of the associated top-down mechanisms and aims at validating a theoretical model on the requirements for successful compensation among drivers with homonymous visual field loss. METHODS: A driving simulator study was conducted with eight participants with homonymous visual field loss and eight participants with normal vision. Participants drove through an urban surrounding and experienced a baseline scenario and scenarios with visual precursors indicating increased likelihoods of crossing hazards. Novel measures for the assessment of the mental model of their visual abilities, the mental model of the driving scene and the perceived attention demand were developed and used to investigate the top-down mechanisms behind attention allocation and hazard avoidance. RESULTS: Participants with an overestimation of their visual field size tended to prioritize their seeing side over their blind side both in subjective and objective measures. The mental model of the driving scene showed close relations to the subjective and actual attention allocation. While participants with homonymous visual field loss were less anticipatory in their usage of the visual precursors and showed poorer performances compared to participants with normal vision, the results indicate a stronger reliance on top-down mechanism for drivers with visual impairments. A subjective focus on the seeing side or on near peripheries more frequently led to bad performances in terms of collisions with crossing cyclists. CONCLUSION: The study yielded promising indicators for the potential of novel measures to elucidate top-down mechanisms in drivers with homonymous visual field loss. Furthermore, the results largely support the model of requirements for successful compensatory scanning. The findings highlight the importance of individualized interventions and driver assistance systems tailored to address these mechanisms.


Assuntos
Condução de Veículo , Campos Visuais , Humanos , Transtornos da Visão , Visão Ocular , Testes de Campo Visual , Acidentes de Trânsito
9.
Ophthalmic Res ; 67(1): 257-265, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38508153

RESUMO

INTRODUCTION: Microcirculation of optic nerve head (ONH) in open-angle glaucoma (OAG) patients with unilateral visual field (VF) loss has yet to be fully investigated, especially the perimetrically unaffected fellow eyes. METHODS: Thirty-eight OAG patients with VF defect in one eye and normal VF in the other eye, and thirty-one healthy participants were analyzed. All participants underwent laser speckle flowgraphy (LSFG), spectral-domain optical coherence tomography (SD-OCT) imaging, and VF test for further analyses. LSFG measurements included mean blur rate in all area of ONH (MA), big vessel area of ONH (MV), and tissue area of ONH (MT). SD-OCT parameters included circumpapillary retinal nerve fiber layer (cpRNFL) thickness and macula thicknesses. The difference of LSFG and SD-OCT indices between glaucoma patients and healthy controls were compared. The diagnostic accuracy was analyzed with the areas under the receiver operating characteristic curves (AROCs). RESULTS: Global cpRNFL thickness and macular thickness in unaffected eyes of OAG patients were higher than their fellow eyes and lower than healthy eyes. MA and MV in healthy eyes and unaffected eyes were significantly higher than in affected eyes. MT in unaffected eyes of OAG patients was higher than in their fellow affected eyes but lower than in healthy eyes. The AROCs were highest for cpRNFL (0.925), followed by macular thickness (0.838), and MT (0.834). CONCLUSIONS: ONH microcirculation in perimetrically unaffected fellow eyes was decreased in OAG patients with unilateral VF loss. LSFG can detect changes of ONH in high-risk eyes before detectable VF damage, which may reflect the vascular pathophysiology for glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Microcirculação , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Masculino , Feminino , Disco Óptico/irrigação sanguínea , Microcirculação/fisiologia , Campos Visuais/fisiologia , Tomografia de Coerência Óptica/métodos , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Idoso , Pressão Intraocular/fisiologia , Testes de Campo Visual , Fluxometria por Laser-Doppler , Curva ROC , Vasos Retinianos/fisiopatologia , Vasos Retinianos/diagnóstico por imagem
10.
Arch. Soc. Esp. Oftalmol ; 99(3): 91-97, Mar. 2024. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-231135

RESUMO

Detectar y caracterizar los defectos del campo visual (CV) mediante perimetría Octopus en pacientes con glaucoma congénito primario (GCP) y determinar la calidad y duración del CV. Material y métodos: Se incluyeron 88 ojos de 70 pacientes diagnosticados de GCP. Las evaluaciones se realizaron con un Octopus 900 y cada ojo se evaluó con el algoritmo de perimetría orientada por tendencias (G-TOP). Se recogieron datos cuantitativos de CV: datos de calidad (respuestas falsa positiva y negativa, y duración del tiempo) y resultados de desviación media (DM) y raíz cuadrada de la varianza de pérdida (sLV). También se recogieron datos cualitativos: presencia de defectos difusos y localizados, hemicampo afectado y grado de defectos utilizando la clasificación de Aulhorn y Karmeyer. Se analizaron las correlaciones entre los resultados perimétricos y las variables clínicas. Resultados: La mediana de edad fue de 11 (8-17) años. El 65,9% (58/88) de los ojos con GCP presentaban defectos de CV. Se observaron defectos difusos en 10/58 ojos (16,94%) (DM media=23,92 [DE: 2,52]) dB) y defectos localizados en 48/58 ojos (82,75%). El defecto más frecuente fue el escotoma incipiente paracentral (n=15), el escalón nasal (n=8), el defecto arciforme añadido (n=2), el semianular (n=13) y el defecto concéntrico con isla central (n=9). El hemicampo visual afectado con mayor frecuencia fue el inferior. La duración media de la prueba fue de 2min 12s (DE: 21,6s). Los valores MD y sLV se correlacionaron con la agudeza visual mejor corregida, la relación excavación/disco y el número de cirugías de glaucoma (todas p<0,001). Conclusión: Se identificó un alto número de defectos difusos y localizados utilizando la perimetría Octopus en pacientes con GCP. El defecto más frecuente fue el escotoma paracentral, y el hemicampo inferior fue el más afectado.(AU)


Purpose: To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration. Material and methods: Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed. ResultsMedian age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD=23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n=15), nasal step (n=8), adding arcuate defect (n=2), half ring-shaped (n=13) and concentric defect with a central island (n=9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2min 12s (SD: 21.6s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P<.001). Conclusion: A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Glaucoma , Testes de Campo Visual/métodos , Cegueira , Anormalidades do Olho , Oftalmologia , Pediatria , Visão Ocular
11.
Sci Rep ; 14(1): 5116, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429373

RESUMO

This prospective cross-sectional study investigated the visual function of preperimetric glaucoma (PPG) patients based on hemifield (HF) pattern electroretinogram (PERG) amplitudes. Thirty-two (32) normal subjects and 33 PPG patients were enrolled in control and PPG groups, respectively. All of the participants had undergone full ophthalmic examinations, including spectral-domain optical coherence tomography (SD-OCT), visual field (VF) examination and pattern electroretinography (PERG). The PERG parameters along with the HF ratios of SD-OCT and PERG were compared between the control and PPG groups. Pairwise Pearson's correlation coefficients and linear regression models were fitted to investigate the correlations. The PERG N95 amplitudes were significantly lower in the PPG group (P < 0.001). The smaller/larger HF N95 amplitude ratio of the PPG group was found to be smaller than that of the control group (0.73 ± 0.20 vs. 0.86 ± 0.12; P = 0.003) and showed positive correlations with affected HF average ganglion cell-inner plexiform layer (GCIPL) thickness (r = 0.377, P = 0.034) and with average GCIPL thickness (r = 0.341, P = 0.005). The smaller/larger HF N95 amplitude ratio did not significantly change with age (ß = - 0.005, P = 0.195), whereas the full-field N95 amplitude showed a negative correlation with age (ß = - 0.081, P < 0.001). HF analysis of PERG N95 amplitudes might be particularly useful for patients with early glaucoma.


Assuntos
Eletrorretinografia , Glaucoma , Humanos , Eletrorretinografia/métodos , Estudos Transversais , Estudos Prospectivos , Testes de Campo Visual/métodos , Glaucoma/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
12.
PLoS One ; 19(3): e0300103, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38457436

RESUMO

PURPOSE: To compare the relationship between macular ganglion cell layer (mGCL) thickness and 10-2 visual field (VF) sensitivity using different stimulus sizes in patients with temporal hemianopia from chiasmal compression. METHODS: A cross-sectional study was conducted involving 30 eyes from 25 patients with temporal VF loss on 24-2 SITA standard automated perimetry due to previous chiasmal compression and 30 healthy eyes (23 controls). Optical coherence tomography (OCT) of the macular area and 10-2 VF testing using Goldmann stimulus size I (GI), II (GII), and III (GIII) were performed in the Octopus 900 perimeter. For the sake of analysis, mGCL thickness and VF data were segregated into four quadrants (two temporal and two nasal) and two halves (temporal and nasal) centered on the fovea, in order to evaluate separately both the severely affected nasal hemi-retina corresponding to the temporal VF sectors and the subclinically affected temporal hemi-retina corresponding to the nasal VF sectors. Data from patients and controls were compared using generalized estimated equations. The discrimination ability of GI, GII, and GIII was evaluated, as was the correlation between mGCL and 10-2 VF sensitivity using GI, GII, and GIII. RESULTS: All mGCL parameters in the nasal and temporal halves of the retina were significantly reduced in patients compared to controls. 10-2 VF test sensitivity using GI, GII, and GIII was significantly lower in patients than in controls (p≤0.008) for all parameters, except the three nasal divisions when using GI (p = 0.41, 0.07 and 0.18) Significant correlations were found between temporal VF sectors (all stimulus sizes) and the corresponding nasal mGCL measurements, with similar discrimination ability. Significant correlations were also observed between all three nasal VF divisions and the corresponding temporal mGCL thickness when using stimulus sizes I and II, but not stimulus size III. CONCLUSIONS: On 10-2 VF testing, GII outperformed GI and GIII with regard to discrimination ability and structure-function correlation with mGCL thickness in the subclinically affected nasal part of the VF in patients with chiasmal compression. Our findings suggest that the use of GII can enhance the diagnostic power of 10-2 VF testing in early cases of chiasmal compression, although further studies are necessary to support this conclusion.


Assuntos
Testes de Campo Visual , Campos Visuais , Humanos , Estudos Transversais , Células Ganglionares da Retina , Hemianopsia , Tomografia de Coerência Óptica/métodos
13.
Clin Exp Optom ; 107(2): 122-129, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38467126

RESUMO

Detecting deterioration of visual field sensitivity measurements is important for the diagnosis and management of glaucoma. This review surveys the current methods for assessing progression that are implemented in clinical devices, which have been used in clinical trials, alongside more recent advances proposed in the literature. Advice is also offered to clinicians on what they can do to improve the collection of perimetric data to help analytical progression methods more accurately predict change. This advice includes a discussion of how frequently visual field testing should be undertaken, with a view towards future developments, such as digital healthcare outside the standard clinical setting and more personalised approaches to perimetry.


Assuntos
Glaucoma , Campos Visuais , Humanos , Testes de Campo Visual/métodos , Glaucoma/diagnóstico , Progressão da Doença , Transtornos da Visão/diagnóstico
14.
Sci Rep ; 14(1): 3380, 2024 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336828

RESUMO

Optical coherence tomography (OCT) has become a key method for diagnosing and staging radiation retinopathy, based mainly on the presence of fluid in the central macula. A robust retinal layer segmentation method is required for identification of the specific layers involved in radiation-induced pathology in individual eyes over time, in order to determine damage driven by radiation injury to the microvessels and to the inner retinal neurons. Here, we utilized OCT, OCT-angiography, visual field testing, and patient-specific dosimetry models to analyze abnormal retinal layer thickening and thinning relative to microvessel density, visual function, radiation dose, and time from radiotherapy in a cross-sectional cohort of uveal melanoma patients treated with 125I-plaque brachytherapy. Within the first 24 months of radiotherapy, we show differential thickening and thinning of the two inner retinal layers, suggestive of microvessel leakage and neurodegeneration, mostly favoring thickening. Four out of 13 eyes showed decreased inner retinal capillary density associated with a corresponding normal inner retinal thickness, indicating early microvascular pathology. Two eyes showed the opposite: significant inner retinal layer thinning and normal capillary density, indicating early neuronal damage preceding a decrease in capillary density. At later time points, inner retinal thinning becomes the dominant pathology and correlates significantly with decreased vascularity, vision loss, and dose to the optic nerve. Stable multiple retinal layer segmentation provided by 3D graph-based methods aids in assessing the microvascular and neuronal response to radiation, information needed to target therapeutics for radiation retinopathy and vision loss.


Assuntos
Lesões por Radiação , Degeneração Retiniana , Neurônios Retinianos , Humanos , Testes de Campo Visual , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Retina/diagnóstico por imagem , Retina/patologia , Neurônios Retinianos/patologia , Degeneração Retiniana/patologia , Lesões por Radiação/etiologia , Lesões por Radiação/patologia
15.
Transl Vis Sci Technol ; 13(2): 2, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38306105

RESUMO

Purpose: To predict Humphrey Field Analyzer 24-2 test (HFA 24-2) results using 10-2 results. Methods: A total of 175 advanced glaucoma eyes (175 patients) with HFA 24-2 mean deviation (MD24-2) of < -20 dB were prospectively followed up for five years using HFA 10-2 and 24-2 (twice and once in a year, respectively). Using all the HFA 24-2 and 10-2 test result pairs measured within three months (350 pairs from 85 eyes, training dataset), a formula to predict HFA 24-2 result using HFA 10-2 results was constructed using least absolute shrinkage and selection operator regression (LASSO). Using 90 different eyes (testing dataset), the absolute differences between the actual and LASSO-predicted MD24-2 and that between the slopes calculated using five actual and LASSO-predicted MD24-2 values, were adopted as the prediction error. Similar analyses were performed for the mean total deviation values (mTD) of the superior (or inferior) hemifield [hemi-mTDsup.24-2(-hemi-mTDinf.24-2)]. Results: The prediction error for the LASSO-predicted MD24-2 and its slope were 2.98 (standard deviation [SD] = 1.90) dB and 0.32 (0.33) dB/yr, respectively. The LASSO-predicted hemi-mTDsup.24-2 (hemi-mTDinf.24-2), and its slope were 3.02 (2.89) and 3.76 (2.72) dB, and 0.37 (0.41) and 0.44 (0.38) dB/year, respectively. These prediction errors were within two times SD of repeatability of the simulated stable HFA 24-2 VF parameter series. Conclusions: HFA 24-2 results could be predicted using the paired HFA 10-2 results with reasonable accuracy using LASSO in patients with advanced glaucoma. Translational Relevance: It is useful to predict HFA24-2 test from HFA10-2 test, when the former is not available, in advanced glaucoma.


Assuntos
Glaucoma , Campos Visuais , Humanos , Testes de Campo Visual/métodos , Glaucoma/diagnóstico , Olho
16.
Turk J Ophthalmol ; 54(1): 11-16, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38385315

RESUMO

Objectives: To evaluate the use of the Amsler grid test (AGT) in screening for age-related macular degeneration (AMD), one of the most common causes of blindness, in primary healthcare settings. Materials and Methods: The AGT was applied to 700 eyes of 355 people aged 50 and over who applied to a family health center in Ankara and had no eye complaints. The test was considered positive if the lines on the AGT card were seen as broken or curved, there was a difference in shape or size between the squares, or a color change or blurring was described in any area. An ophthalmologist was consulted if the AGT was positive in one or both eyes. Patients considered suitable by ophthalmologists were evaluated with optical coherence tomography. AGT results were compared with ophthalmologist examination and tomography findings in terms of AMD detection. Results: The AGT was positive in 97 (13.9%) and negative in 603 (86.1%) out of 700 eyes included in the study. A total of 184 eyes, 79 with a positive AGT and 105 eyes with a negative test, were evaluated by an ophthalmologist. As a result of examinations and tests performed by ophthalmologists, AMD was detected in a total of 67 eyes: 42 of 79 eyes with positive AGT and 25 of 105 eyes with negative AGT but referred to an ophthalmologist for different reasons. In our study, the AGT had 62.7% sensitivity and 68.4% specificity. Conclusion: The AGT is an inexpensive and easily applicable test. Although moderate sensitivity and specificity were found in our study; further studies are needed to evaluate the suitability of its use for AMD screening in primary care with limited facilities.


Assuntos
Degeneração Macular , Testes de Campo Visual , Humanos , Pessoa de Meia-Idade , Idoso , Acuidade Visual , Testes de Campo Visual/métodos , Degeneração Macular/diagnóstico , Sensibilidade e Especificidade , Tomografia de Coerência Óptica
17.
Ophthalmic Physiol Opt ; 44(3): 605-612, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38351866

RESUMO

PURPOSE: To explore the mechanisms of cone sensitivity loss in retinitis pigmentosa by combining two-colour perimetry with threshold versus intensity (tvi) testing. METHODS: Seven subjects with autosomal recessive retinitis pigmentosa and 10 normal subjects were recruited and underwent perimetric testing of one eye using 480- and 640-nm Goldman size V targets presented under scotopic conditions (no background illumination) and against a white background ranging in luminance from -1.5 to 2 log cd m-2 in 0.5 log cd m-2 steps. Data were fitted with tvi functions of the form logT = logT0 + log ((A + A0)/A0)n, where T is the threshold, T0 is the absolute threshold, A is the background intensity, A0 is the 'dark-light' constant and n is a gain constant. RESULTS: Reliable tvi functions could not be obtained within the region of the visual field corresponding to loss of the ellipsoid zone on optical coherence tomography. At fixation, changes in both T0 and A0 were observed, consistent with a d1 mechanism loss, which resulted in an upwards and rightwards shift of the tvi function. Losses at [±3°, ±3°] demonstrated changes in T0, consistent with a d3 mechanism loss, resulting in an upwards translation of the tvi curve. CONCLUSIONS: Although the absolute cone threshold was elevated at each location, shifts in the tvi function (so-called d1 mechanism loss) at fixation minimise threshold elevation in the presence of white adapting backgrounds, such as those typically employed in standard two-colour perimetry. At more peripheral testing locations, changes in threshold occurred independent of background luminance (so-called d3 mechanism loss). These findings suggest that backgrounds which selectively adapt rods while maintaining cones at, or near, absolute threshold may be preferable to conventional two-colour perimetry for assessing loss of cone sensitivity, especially at the point of fixation.


Assuntos
Células Fotorreceptoras Retinianas Cones , Retinite Pigmentosa , Humanos , Adaptação à Escuridão , Retinite Pigmentosa/diagnóstico , Campos Visuais , Visão Ocular , Testes de Campo Visual/métodos , Eletrorretinografia
19.
Int Ophthalmol ; 44(1): 107, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386180

RESUMO

PURPOSE: The current study utilizes microperimetry and optical coherence tomography angiography (OCTA) to assess the optic nerve head vasculature, retinal microvasculature, and retinal sensitivity before and after silicone oil (SO) removal. METHODS: This prospective observational case series study involved 30 eyes subjected to silicone oil endotamponade. Microperimetry and OCTA were utilized to assess the vascular density (VD) of the macula and optic nerve head, as well as the retinal sensitivity (RS), of the participants preoperatively and 1 month following SO removal. The correlation between the various parameters of OCTA and microperimetry was evaluated. RESULTS: There was a significant improvement in the postoperative best-corrected visual acuity (BCVA) (p-value < 0.001) and the postoperative total RS, which was 6.38 ± 2.34 dB as compared to a mean preoperative total RS of 5.04 ± 2.06 dB (p-value < 0.001) and showing a significant increase in all rings. However, there was no significant difference in the pre and postoperative macular VD. On the other hand, there was a significant increase in the postoperative VD of the whole disk and the peripapillary capillary plexus, p-values < 0.001 and 0.002, respectively. CONCLUSION: The removal of SO resulted in significant improvements in retinal sensitivity, vision, and optic nerve perfusion. However, no significant change was observed in macular VD. CLINICAL TRIALS: gov Identifier: NCT04928196.


Assuntos
Macula Lutea , Descolamento Retiniano , Humanos , Óleos de Silicone , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/cirurgia , Tomografia de Coerência Óptica , Testes de Campo Visual , Perfusão , Angiografia
20.
Invest Ophthalmol Vis Sci ; 65(2): 35, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38393715

RESUMO

Purpose: The Ocular Hypertension Treatment Study (OHTS) identified risk factors for primary open-angle glaucoma (POAG) in patients with ocular hypertension, including pattern standard deviation (PSD). Archetypal analysis, an unsupervised machine learning method, may offer a more interpretable approach to risk stratification by identifying patterns in baseline visual fields (VFs). Methods: There were 3272 eyes available in the OHTS. Archetypal analysis was applied using 24-2 baseline VFs, and model selection was performed with cross-validation. Decomposition coefficients for archetypes (ATs) were calculated. A penalized Cox proportional hazards model was implemented to select discriminative ATs. The AT model was compared to the OHTS model. Associations were identified between ATs with both POAG onset and VF progression, defined by mean deviation change per year. Results: We selected 8494 baseline VFs. Optimal AT count was 19. The highest prevalence ATs were AT9, AT11, and AT7. The AT-based prediction model had a C-index of 0.75 for POAG onset. Multivariable models demonstrated that a one-interquartile range increase in the AT5 (hazard ratio [HR] = 1.14; 95% confidence interval [CI], 1.04-1.25), AT8 (HR = 1.22; 95% CI, 1.09-1.37), AT15 (HR = 1.26; 95% CI, 1.12-1.41), and AT17 (HR = 1.17; 95% CI, 1.03-1.31) coefficients conferred increased risk of POAG onset. AT5, AT10, and AT14 were significantly associated with rapid VF progression. In a subgroup analysis by high-risk ATs (>95th percentile or <75th percentile coefficients), PSD lost significance as a predictor of POAG in the low-risk group. Conclusions: Baseline VFs, prior to detectable glaucomatous damage, contain occult patterns representing early changes that may increase the risk of POAG onset and VF progression in patients with ocular hypertension. The relationship between PSD and POAG is modified by the presence of high-risk patterns at baseline. An AT-based prediction model for POAG may provide more interpretable glaucoma-specific information in a clinical setting.


Assuntos
Glaucoma de Ângulo Aberto , Hipertensão Ocular , Disco Óptico , Humanos , Campos Visuais , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/epidemiologia , Glaucoma de Ângulo Aberto/complicações , Pressão Intraocular , Hipertensão Ocular/tratamento farmacológico , Aprendizado de Máquina , Transtornos da Visão , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...